Gabled

Frame structures - Gabled

Type G

  • roof does not project beyond the frame outline
  • stable steel structure
  • roofing: 6 mm cellular polycarbonate with UV filter
  • water discharged by steel gutters
  • complete multiplications can be formed

G BS

  • 100% galvanised and powder-coated steel
  • panes: 6 mm toughened glass
  • roof: 6 mm cellular polycarbonate with UV filter
  • 4 foundation points
  • multiplication possibility
  • full statics for all locations
  • shelter closing accessories for shelters with 3 panes:
  • BW, SH, RD, TD unavailable

G ST

  • 100% galvanised and powder-coated steel
  • panes: 6 mm toughened glass
  • roof: 6 mm cellular polycarbonate with UV filter
  • 6 foundation points
  • multiplication possibility
  • full statics for all locations

G LONG

  • 100% galvanised and powder-coated steel
  • panes: 6 mm toughened glass
  • roof: 6 mm cellular polycarbonate with UV filter
  • 8 foundation points
  • multiplication possibility
  • full statics for all locations

G W

  • 100% galvanised and powder-coated steel
  • constructional laminated timber
  • panes: 6 mm toughened glass
  • roof: 6 mm cellular polycarbonate with UV filter
  • 6 foundation points
  • multiplication possibility
  • full statics for all locations

Type R

  • roof projects beyond the frame outline
  • stable steel structure
  • roofing: 6 mm cellular polycarbonate with UV filter
  • water discharged by steel angle
  • series of frames can be formed

R BS

  • 100% galvanised and powder-coated steel
  • panes: 6 mm toughened glass
  • roof: 6 mm cellular polycarbonate with UV filter
  • 4 foundation points
  • multiplication possibility
  • full statics for all locations
  • shelter closing accessories for shelters with 3 panes:
  • BW, SH, RD, TD unavailable

R ST

  • 100% galvanised and powder-coated steel
  • panes: 6 mm toughened glass
  • roof: 6 mm cellular polycarbonate with UV filter
  • 6 foundation points
  • multiplication possibility
  • full statics for all locations

R LONG

  • 100% galvanised and powder-coated steel
  • panes: 6 mm toughened glass
  • roof: 6 mm cellular polycarbonate with UV filter
  • 8 foundation points
  • multiplication possibility
  • full statics for all locations

R W

  • 100% galvanised and powder-coated steel
  • constructional laminated timber
  • panes: 6 mm toughened glass
  • roof: 6 mm cellular polycarbonate with UV filter
  • 6 foundation points
  • multiplication possibility
  • full statics for all locations
  • series of frames can be formed